| WOR |
|
RADIO FREQUENCY
|
| Frequency: |
318 MHz |
| Bandwidth: |
300 KHz minimum |
| Image Rejection: |
40 dB |
| LO Reradiation: |
200 µV/meter @3 meters (maximum) |
| Data Format: |
MegaCode |
| Sensitivity: |
-100 dB minimum |
| Desensitivity: |
20 dB manual attenuation at the antenna input |
|
INPUTS
|
| Power: |
Terminal block input "+" and "Gnd"; input voltage 5 Vdc regulated or unregulated between +6 to +24 Vdc with reverse polarity protection |
| Hold: |
Terminal block input "Hold"; follows standard Wiegand hold line conventions; hold line can be overridden via dip switch
|
| Antenna: |
9-1/2 in whip antenna with F-connector (supplied) |
|
OUTPUTS
|
| Data: |
Terminal block output "Data 0" and "Data 1" standard Wiegand electrical and protocol interface |
| LEDs: |
Red RF activity LED indicates RF activity at 318 MHz; red/green decode LED is green during Wiegand data transmissions and receiver hold timing window (if enabled) after any output transmission; otherwise it is off unless hold enable is selected, in which case LED will remain red until hold is removed by host system |
|
CONTROLS
|
| Pushbutton: |
Momentary switch labeled "Program" used to configure microprocessor after system option selection and configuration |
|
DIP SWITCHES
|
| Receiver Facility Code: |
Four positions to select 1 of 16 possible MegaCode facility codes; if code 0 is selected, the receiver will validate any received facility code; any other selection requires the transmitters' facility code to match the receiver facility code selection for validation |
| Output Facility Code: |
16 positions to select one of 65,536 possible facility codes; a selected output format may not use all 16 bits |
| Output Format: |
3 positions for selecting either 26, 30, or 31bit Wiegand output format |
| Button Disable: |
5 positions, each corresponding to 1 of 5 possible MegaCode transmitter buttons - left or top left, right or top right, bottom left, bottom right, top
|
| Receiver Lockout Disable: |
1 position; if set to ON, the 1 second receiver lockout is not performed |
| Button Offset: |
1 position; if set to ON, the transmitter ID number is offset with a number based on which button is pressed:
| Button |
Offset |
|
Left
|
0
|
|
Right
|
16384
|
|
Bottom Left
|
32768
|
|
Bottom Right
|
49152
|
|
| Wiring: |
up to 300 feet with 24 AWG, 500 feet with 20 AWG; up to 1,000 feet, CAT-5 |
| Enclosure: |
Weather-resistant, anodized aluminum enclosure with removable end caps to provide wiring and programming access; end caps secured with screws |
| Operating Temperature: |
-22° to +155° F (-30° to +70° C) |
| Electrical: |
Robust RFI and ESD protection for all inputs and outputs, including antenna input; protection to prevent output errors during brownouts |
| Literature |
|